Home > Published Issues > 2013 > Volume 2, No. 4, October 2013 >

Study of Wear Behavior of HVOF and Cold Sprayed Coatings on Boiler Steels

Jasbir Singh1 , Harvinder Lal1, and Niraj Bala2
1.Ramgarhia Institute of Engineering and Technology (RIET), REC Complex Phagwara
2.BBSBEC Fatehgarh Sahib, Punjab, India 140407

Abstract—In this study two commonly used steels in boiler plants, i.e. (SAE-213) T-22 and SA516 (Grade- 70) were coated with different thermal spray processes namely HVOF and cold spray. The coating powder used was made up of NiCrTiCRe powder. The performance of the coated as well as uncoated material was investigated using a pin-on-disc machine [Model: Wear and Friction Monitor Tester TR-20], supplied by M/S DUCOM, Bangalore (INDIA) wear using different loads.

Index Terms—T-22 and SA516 steels, Cold spray process and HVOF spray process, NiCrTiCRe coatings

Cite: Jasbir Singh, Harvinder Lal, and Niraj Bala, " Study of Wear Behavior of HVOF and Cold Sprayed Coatings on Boiler Steels," International Journal of Mechanical Engineering and Robotics Research, Vol. 2, No. 4, pp. 134-138, October 2013.